SYMBOLOGIES 11 - 179
CLSI Editing
Parameter # 54
Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth
characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format.
Options:
Enable CLSI Editing
*Disable CLSI Editing.
Enable CLSI Editing
(01h)
NOTE Symbol length does not include start and stop characters.