USB INTERFACE BAR CODES 1 - 21
Scan Disable Mode
Parameter # 1214
This parameter determines the behavior of the MP6000 when it receives a Scan Disable directive from the
connected host.
Options:
*Full Disable - Scanning bar codes is disabled.
Transmit Disable - The MP6000 may scan bar codes, but transmission of bar code data is disabled.
Auto Disable - MP6000 disables scanning after transmission of a bar code, and remains disabled until
the host sends a Scan Enable.
* Full Disable
(0)
NOTE This feature is currently supported by IBM Table Top USB, IBM Hand-held USB, and all IBM 46XX
interfaces.