102 170PAX 4 User Guide 10/12/2004 57516L-001 Rev. 1
Troubleshooting
Print Engine Diagnostics
PAUSE Self Test
This self test can be used to provide the test labels required when making adjustments to the
print engine’s mechanical assemblies. Figure 49 shows a sample printout.
To perform a PAUSE self test, complete these steps:
1. Turn Off (O) the print engine.
2. Press and hold PAUSE while turning the power On (I). Hold PAUSE until the DATA light
turns off.
The initial self test prints 15 labels at the print engine’s slowest speed, and then
automatically pauses the print engine. Each time
PAUSE is pressed, an additional 15
labels print. Figure 49 shows a sample of the labels.
Figure 49 • PAUSE Test Label
While the print engine is paused, pressing
CANCEL alters the self test. Each time
PAUSE is pressed, 15 labels print at 6 in. (152 mm) per second.
While the print engine is paused, pressing
CANCEL again alters the self test a second
time. Each time
PAUSE is pressed, 50 labels print at the print engine’s slowest speed
While the print engine is paused, pressing
CANCEL again alters the self test a third
time. Each time
PAUSE is pressed, 50 labels print at 6 in. (152 mm) per second.
While the print engine is paused, pressing
CANCEL again alters the self test a fourth
time. Each time
PAUSE is pressed, 15 labels print at the print engine’s maximum
speed.
To exit this self test at any time, press and hold
CANCEL.