18 Zebra S400 & S600 User’s Guide
$GMXVWLQJWKH0HGLD6HQVRU
This adjustment aligns the position of the light sensor with the notch or
edge of the label, so the printer can determine the correct label size.
See Figure 13. With the printhead open, look through the side of the print
mechanism and locate the media sensor adjustment lever (a). Reposition
the sensor until the top of the adjustment lever is in line with the notch or
web in the media or the edge of the label. Close the printhead by moving
the head open lever to the closed position.
When continuous media (no notch or opening to sense) is used, position
the media sensor anywhere over the media so that an “out-of-media
condition is sensed.
Figure 13. Media Sensor Adjustment