Zebra T402 Guida Utente Pagina 55

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 54
Serial(RS-232)ConnectorTechnical
Information
NOTES:Themaximumcurrentavailablethroughtheserial
and/orparallelportisnottoexceedatotalof0.75Amps.
WhenXON/XOFFhandshakingisselected,dataflowiscontrolled
bytheASCIIcontrolcodesDC1(XON)andDC3(XOFF).The
DTRcontrolleadwillhavenoeffect.
InterconnectingtoDTEDevices
Theprinterisconfiguredasdataterminalequipment(DTE).Toconnectthe
printertootherDTEdevices(suchastheserialportofapersonal
computer),useanRS-232nullmodem(crossover)cable.
Figure38showstherequiredcableconnections.
InterconnectingtoDCEDevices
WhentheprinterisconnectedviaitsRS-232interfacetodata
communicationequipment(DCE)suchasamodem,aSTANDARD
RS-232(straight-through)interfacecablemustbeused.Figure39shows
theconnectionsrequiredforthiscable.
49
PinNo. Description
1
Notused
2
RXD(receivedata)inputtotheprinter
3
TXD(transmitdata)outputfromtheprinter
4
DTR(dataterminalready)outputfromtheprinter--controlswhen
thehostmaysenddata
5
Chassisground
6
DSR(datasetready)inputtotheprinter
7
RTS(requesttosend)outputfromtheprinter--alwaysinthe
ACTIVEconditionwhentheprinteristurnedon
8
Notused
9
5V@0.75Afused
Vedere la pagina 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60

Commenti su questo manuale

Nessun commento