PA/PT400 & PA/PT 403 User’s Guide 29
6. Press the Feed button. One entire blank label should feed. If
this doesn’t happen, try defaulting (refer to “Feed Button
Modes” in the “Troubleshooting” section) and recalibrating the
printer.
NOTES: Performing a manual calibration disables the
auto calibration function. To return to auto calibration,
either default the printer (see “Feed Button Modes” in
“Troubleshooting”) or refer to your label preparation soft-
ware users manual.
When using non-continuous media, set the appropriate
software command (see your label preparation software
users manual) before you perform a manual calibration.