Zebra II Specifiche Pagina 166

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 412
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 165
ZPL Commands
^FO
146
45541L-004 Rev. A ZPL II Programming Guide 9/15/06
^FO
Field Origin
Description The ^FO command sets a field origin, relative to the label home (^LH)
position.
^FO sets the upper-left corner of the field area by defining points along the
x-axis and y-axis independent of the rotation.
Format ^FOx,y
This table identifies the parameters for this format:
Comments If the value entered for the
x or y parameter is too high, it could position the
field origin completely off the label.
Parameters Details
x = x-axis location
(in dots)
Accepted Values: 0 to 32000
Default Value: 0
y = y-axis location
(in dots)
Accepted Values: 0 to 32000
Default Value: 0