c = application mode start signal print
Accepted Values:
p = pulse mode Start Print signal must be de-asserted before it
can be asserted for the next label.
l = level mode Start Print signal does not need to be de-asserted
to print the next label. As long as the Start Print signal is low
and a label is formatted, the printer will print a label.
Default Value: 0
d = application label error mode
Accepted Values:
e = error mode the printer will assert the “Service Required”
signal (svce_req - pin 10) on the application port, enter into
pause mode, and display an error message on the LCD
display.
f = feed mode the printer will print a blank label when the web is
not found where expected to synch the printer to the media.
Default Value: f
e = reprint mode
Accepted Values:
e = enabled printer will ignore the reprint signal.
d = disabled printer will reprint the last label printed after the
signal is asserted. If a label is canceled, the label to be
reprinted will also be canceled. This mode consumes more
memory because the last printed label is not released until
reprint.
Default Value: d
f = ribbon low mode
Accepted Values:
e = enabled printer warning issued when ribbon low.
d = disabled printer warning not issued when ribbon low.
Default Value: e