Comments: Incrementing and decrementing takes place for each serial-numbered
field when all replicates for each serial number have been printed, as specified in
parameter r of the ^PQ (print quality) command.
If, during the course of printing serialized labels the printer runs out of either paper
or ribbon, the first label printed (after the media or ribbon has been replaced and
calibration completed) will have the same serial number as the “partial” label printed
before the “out” condition occurred. This is done in case the last label before the
“out” condition did not fully print. This is controlled by the ^JZ command.
ZPL II Programming Guide Volume One: Command Reference for X.10